\begin{table}%T3 \caption{\label{noises}Parameters of the observations and of the final full resolution~maps.} \smallskip %\centerline { \begin{tabular}{ccccccc} \hline \hline \noalign{\smallskip} Wavelength & Full resolution & Largest detectable structure & ${\sigma_{\rm F}}^a$ & ${\sigma_{\rm th}}^b$ & ${\sigma_{\rm conf_{\rm center}}} ^c$ & ${\sigma_{\rm obs_{\rm center}}} ^d$ \\ & ${\arcsec}$ & $^{\prime}$ & & mJy/beam & mJy/beam & mJy/beam \\ \hline 2~m & 163~$\times$~181 & 191 & 5\% & 0.85 & 3 & 3.1 \\ \hline 85~cm & 54~$\times$~64 & 81 & 1\% & 0.05 & 0.25 & 0.25 \\ \hline 25~cm & 14~$\times$~15 & 24 & 1\% & 0.010 & 0.008 & 0.012 \\ \hline \end{tabular}} \smallskip {$^a$ Flux scale uncertainty.}\\ {$^b$ Thermal noise, constant over the~maps.}\\ {$^c$ Confusion noise.}\\ {$^d$ Observed noise at the pointing position.} \end{table}