\begin{table}%t2 \caption{\label{tab:Tab2}Linearity fit parameters and their quality ($b>1$ denotes super-linear and $b<1$ sub-linear behavior).} %\centering \par \begin{tabular}{clll} \hline\hline ch.\# & detector & Measurement, $\lambda$ & Parameter $b$ ($\pm$uncertainty)\\ \hline \multicolumn{4}{l}{\it Unit 1} \\ %\hline 1-1 & MSM12 & NI 121.6~nm & 1.018 (0.018)\\ 1-2 & PIN10 & NI 210~nm & 1.010 (0.002)\\ 1-3 & MSM11 & NI 50~nm & 1.131 (0.046)\\ 1-3 & MSM11 & GI 18~nm & 1.179 (0.007)\\ 1-4 & AXUV-20D & GI 10~nm & 1.018 (0.002)\\ \hline \multicolumn{4}{l}{\it Unit 2} \\ %\hline 2-1 & MSM21 & NI 121.6~nm & 1.033 (0.010)\\ 2-2 & PIN11 & NI 210~nm & 1.006 (0.004)\\ 2-3 & MSM15 & NI 50~nm & 1.022 (0.038)\\ 2-3 & MSM15 & GI 18~nm & 1.090 (0.005)\\ 2-4 & MSM19 & GI 10~nm & 1.086 (0.009)\\ \hline \multicolumn{4}{l}{\it Unit 3} \\ %\hline 3-1 & AXUV-20A & NI 121.6~nm & 1.039 (0.010)\\ 3-2 & PIN12 & NI 210~nm & 0.989 (0.005)\\ 3-3 & AXUV-20B & NI 50~nm & 0.978 (0.011)\\ 3-3 & AXUV-20B & GI 18~nm & 1.001 (0.001)\\ 3-4 & AXUV-20C & GI 10~nm & 0.998 (0.002)\\ \hline \end{tabular} \end{table}