\begin{table}%t2 \caption{\label{Table2}Thickness and density of the samples, stopping powers and the investigated dose ranges.} %\centering \small \begin{tabular}{l c c c c} \hline\hline\noalign{\smallskip} Sample & Thickness & $\varrho$ & Stopping\tablefootmark{a} & Dose range \\ & ($\mu$m) & (g~cm$^{-3}$)& (eV~$\AA^{-1}$) & (eV/16~u) \\ \hline\noalign{\smallskip} CO:SO$_2$ = 5:1 & 0.776 & 0.99\tablefootmark{b} & 7.5 & 1.3--80.7 \\ CO/SO$_2$ layer & 0.480/0.318 & 0.8\tablefootmark{c}/1.93\tablefootmark{d} & 6.2/14.2 & 1.3--39.8 \\ CO:H$_2$S = 10:1 & 0.662 & 0.83\tablefootmark{b} & 6.6 & 1.3--42.2 \\ CO:H$_2$S = 1:10 & 0.356 & 1.26\tablefootmark{b} & 10.0 & 1.3--42.1 \\ CO/H$_2$S layer & 0.325/0.148 & 0.8\tablefootmark{c}/1.31\tablefootmark{b} & 6.1/10.8 & 1.3--42.2 \\ \hline \end{tabular} \tablefoot{\tablefoottext{a}{Stopping power of 200~keV protons calculated by the SRIM software (Ziegler et~al. \cite{ziegler96})}; \tablefoottext{b}{this work}; \tablefoottext{c}{Loeffler et~al. (\cite{loeffler05})}; \tablefoottext{d}{Rudolph (\cite{rudolph77})}.} \end{table}