\begin{table}%t3 \caption{\label{tab:Table_scs}SCS flight units performance summary.} %\centering \par \begin{tabular}{cccccccc} \hline\hline\noalign{\smallskip} SCS Unit & Warm Rad. & 3 $^{\rm rd}$VGroove & \multicolumn{2}{c}{Cold-end $T$(K)}& Heat lift & Input power & Cycle time \\ & $T$(K) & $T$(K) & HFI I/F & LFI I/F & (mW) & (V) & (s) \\ \hline\noalign{\smallskip} & 270.5 & 45 & 17.2 & 18.7\tablefootmark{a,b}& 1100 & 297 & 940 \\ Redundant & 277 & 60 & 18.0 & 20.1\tablefootmark{a,b}& 1100 & 460 & 492 \\ & 282.6 & 60 & 18.4 & 19.9\tablefootmark{a,b}& 1050 & 388 & 667 \\ \hline Nominal & 270 & 47 & 17.1 & 18.7\tablefootmark{a} & 1125 & 304 & 940 \\ & 273 & 48 & 17.5 & 18.7\tablefootmark{a} & N/A\tablefootmark{c}& 470 & 525\\ \hline \end{tabular} \tablefoot {\tablefoottext{a}{Measured at temperature stabilization assembly (TSA) stage;} \tablefoottext{b}{in SCS-redundant test campaign TSA stage active control was not enabled;} \tablefoottext{c}{not measured.}} \vspace{-3mm}\end{table}