\begin{table}%t1 \caption{\label{JMLTab:Goal_sensitivity}HFI design goals. P stands for polarisation sensitive bolometers. } %\centering \par \begin{tabular}{l*{10}{c}} \hline \hline \noalign{\smallskip} Channel & & 100P & 143P &143 &217P &217 & 353P & 353 & 545 & 857 \\ \hline Central frequency & (GHz) & 100 & 143 &143 &217 &217 & 353 & 353 & 545 & 857 \\ Bandwidth & (\%) & 33\% & 33\% & 33\% & 33\% & 33\% & 33\% & 33\% & 33\% & 33\% \\ Full width half maximum beam size & (\arcmin) &9.6 &7.0 &7.0 &5.0 &5.0 &5.0 &5.0 &5.0 & 5.0 \\ Number of bolometers & &8 &8 &4 &8 &4 &8 &4 &4 &4 \\ NE$\Delta$$T_{\rm CMB}$ per bolometer & ($\rm \mu K_{CMB}~s^{1/2}$) & 100 & 82 & 62 & 132 & 91 & 404 & 277 & 2000 & 91~000 \\ NE$\Delta$$T_{\rm R-J}$ per bolometer & ($\rm \mu K_{R-J}~s^{1/2}$) & 77 & 50 & 38 & 45 & 31 & 34 & 23 & 14 & 9.4 \\ Bolometer NEP & ($\rm aW~s^{1/2}$) & 10.6 & 9.7 & 14.6 & 13.4 & 18.4 & 16.4 & 22.5 & 72.3 & 186 \\ \hline \end{tabular} \vspace*{3mm} \end{table}