Free Access
Table A.1
Parameters used to estimate sensitivity of synthetic tracking camera.
| Value | Unit/notes | |
|
|
||
| Input values: | ||
| Nominal H magnitude | H = 22 mag | size: ~140 m |
| NEO limiting magnitude | 20.49 | |
| NEO distance | 0.362 | au |
| Transverse velocity | 12 | km s-1 |
| Phase angle | 0 | deg |
| Telescope diameter | 100.0 | mm |
| Total QE | 0.64 | |
| Pixel size | 3.30 | ′′ |
| Detector read noise | 1.20 | e− |
| Frame time | 10.00 | s |
| Total integration time | 800.00 | s |
| Total FOV | 14.10 | (″)2 |
| Sky background | 22.0 | mag/(′′)2 |
| 0V-mag reference | 2.48 × 1010 | phot/m2/s |
|
|
||
| Derived values: | ||
| Apparent magnitude | 20.49 | mag |
| Flux detected | 0.72 | e−/s |
| Noise/frame variance | 83.86 | e− |
| Signal/frame | 7.17 | e− |
|
|
||
| Total S/N | 7.00 | in 800 s |
Notes. Total QE describes a combined QE, which includes the system’s optical throughput and detector QE; otherwise detector QE is used.