Table 3.

SO/PHI nominal optical parameters.

HRT FDT
Working wavelength λ0 617.3 nm ± 0.1 nm 617.3 nm ± 0.1 nm
Effective focal length feff 4125.3 mm 579 mm
Field of view αFOV 0.28° ×0.28° ⌀ 2°
Entrance pupil diameter D 140 mm 17.5 mm
Effective F-ratio F# 29.5 33.1
PMP telecentricity < 0.3° < 0.3°
Effective focal length at etalon focus fetalon 7920 mm 1111.7 mm
F# at etalon focus F#etalon 56.6 63.5
Etalon telecentricity < 0.23° < 0.23°
Used detector size 2048 × 2048 pixels 2048 × 2048 pixels
Pixel size dpixel 10 μm 10 μm
Plate scale αpixel
Image quality σWFE λ0/14 (diffraction limit) λ0/14 (diffraction limit)