Free Access

Table 4.

Best fit parameter values for the PION components fitted to the 2000 (top) and 2014 (bottom) RGS and EPIC-PN combined spectra.

Obs. PION NH log ξ vturb vout Ccov= EM ΔC
component (1025 m−2) (10−9 W m) (km s−1) (km s−1) Ω/4π 1069 (m−3)
2000 EM1 3.91 ± 0.02 0.19 ± 0.01 2200
EM2 41 ± 2 0.63 ± 0.01 370 ± 10 −260 ± 10 0.03 ± 0.01 35 600
EM3 22 ± 1 1.84 ± 0.01 890 ± 20 −110 ± 10 0.04 ± 0.01 4700
EM4 18 ± 1 0.02 ± 0.01 220

2014 EMA 8600
EMB 51 ± 1 0.67 ± 0.01 410 ± 10 −300 ± 10 0.02 ± 0.01 510 ± 260 76 100
EMC 1.91 ± 0.01 920 ± 20 −230 ± 10 0.04 ± 0.01 33 ± 10 5740
EMD 0.01 ± 0.01 <1.7 1000

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.