Open Access
Table B.3
Systemic parameters refined from the transit light curves observed with TESS.
ib (°) | ab/R✶ | Rb/R✶ | u1,TESS | u2,ESS | Source |
---|---|---|---|---|---|
HATS-18 b | |||||
![]() |
![]() |
0.1289 ± 0.0021 | ![]() |
![]() |
this paper |
![]() |
![]() |
0.1347 ± 0.0019 | … | … | Penev et al. (2016) |
88.2 ± 1.8 | 3.807 ± 0.052 | 0.13426 ± 0.00095 | … | … | Southworth et al. (2022) |
… | ![]() |
![]() |
![]() |
![]() |
Patel & Espinoza (2022) |
HIP 65A b | |||||
![]() |
![]() |
![]() |
0.50a | 0.23a | this paper |
![]() |
![]() |
![]() |
0.545 ± 0.037 | 0.195 ± 0.041 | Nielsen et al. (2020) |
![]() |
![]() |
![]() |
![]() |
![]() |
Wong et al. (2020) |
TrES-3 b | |||||
![]() |
![]() |
![]() |
0.31a | 0.27a | this paper |
![]() |
![]() |
![]() |
… | … | Saha et al. (2021) |
… | ![]() |
![]() |
![]() |
![]() |
Patel & Espinoza (2022) |
WASP-19b | |||||
![]() |
![]() |
0.1446 ± 0.0018 | ![]() |
![]() |
this paper |
78.76 ± 0.13 | 3.4521 ± 0.0077 | 0.14259 ± 0.00023 | … | … | Mancini et al. (2013) |
![]() |
![]() |
![]() |
… | … | Cortés-Zuleta et al. (2020) |
![]() |
![]() |
![]() |
![]() |
![]() |
Wong et al. (2020) |
![]() |
![]() |
![]() |
![]() |
![]() |
Rosário et al. (2022) |
… | ![]() |
![]() |
![]() |
![]() |
Patel & Espinoza (2022) |
WASP-43 b | |||||
81.99 ± 0.16 | ![]() |
![]() |
![]() |
![]() |
this paper |
82.33 ± 0.20 | ![]() |
![]() |
… | … | Gillon et al. (2012) |
82.11 ± 0.10 | 4.867 ± 0.023 | 0.15942 ± 0.00041 | … | … | Hoyer et al. (2016) |
![]() |
![]() |
![]() |
![]() |
![]() |
Wong et al. (2020) |
82.18 ± 0.11 | ![]() |
![]() |
0.426 ± 0.037 | 0.275 ± 0.040 | Davoudi et al. (2021) |
… | ![]() |
![]() |
![]() |
![]() |
Patel & Espinoza (2022) |
WASP-173A b | |||||
![]() |
![]() |
0.0901 ± 0.0009 | ![]() |
![]() |
this paper |
85.2 ± 1.1 | 4.78 ± 0.17 | 0.1109 ± 0.0009 | … | … | Hellier et al. (2019) |
![]() |
![]() |
![]() |
… | … | Labadie-Bartz et al. (2019) |
![]() |
![]() |
![]() |
![]() |
![]() |
Wong et al. (2020) |
Notes.a Interpolated from the theoretical tables of Claret & Bloemen (2011) and varied under the Gaussian penalty of the width of 0.1 for u1,TESS and 0.2 for u2,TESS.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.