Parameters used in the SED modelling.

Parameter Free/Frozen Fit range/Value
R Frozen 1016 cm
RH Frozen 2 × 1018 cm
Γ Frozen 20
N Free [10−7, 107] cm−3
B Free [10−7, 100] G
θ Free [10−6, 12] deg
γmin Frozen 103
γmax Free [104, 2 × 109]
γbreak Free [10, 109]
p1 Free [10−6, 10]
p2 Free [10−6, 10]

Notes. The table lists whether each parameter was frozen or free during the fit, and the corresponding range over which fitting was performed.