Table A.1.
Observed line parameters of phenalene in TMC-1.a
| Transitionb | νobs c | ∫ TA* dv d | Δve | TA* f |
|---|---|---|---|---|
| (MHz) | (mK km s−1) | (km s−1) | (mK) | |
| 27β, 26-26β, 25 | 31101.252±0.010 | 0.90±0.32 | 0.81±0.35 | 1.03±0.21 |
| 28α, 28-27α, 27 | 31109.488±0.010 | 0.39±0.19 | 0.51±0.24 | 0.70±0.19 |
| 19λ, 9-18λ, 8 | 32129.188±0.010 | 0.33±0.10 | 0.62±0.30 | 0.50±0.11 |
| 21ι, 13-20ι, 12 | 32137.269±0.010 | 0.36±0.12 | 0.72±0.24 | 0.47±0.09 |
| 22θ, 15-21θ, 14 | 32144.436±0.010 | 0.91±0.11 | 1.20±0.21 | 0.71±0.09 |
| 23η, 17-22η, 16 | 32152.173±0.010 | 0.51±0.11 | 0.90±0.21 | 0.53±0.08 |
| 24ζ, 19-23ζ, 18 | 32160.171±0.010 | 0.41±0.12 | 0.93±0.37 | 0.41±0.07 |
| 25ϵ, 21-24ϵ, 20 | 32168.288±0.010 | 0.35±0.10 | 0.71±0.22 | 0.46±0.08 |
| 26δ, 23-25δ, 22 | 32176.490±0.010 | 0.44±0.07 | 0.76±0.15 | 0.53±0.11 |
| 27γ, 25-26γ, 24 | 32184.712±0.010 | 0.49±0.09 | 0.74±0.15 | 0.62±0.12 |
| 28β, 27-27β, 26 | 32192.950±0.010 | 0.45±0.12 | 0.69±0.21 | 0.60±0.10 |
| 29α, 29-28α, 28 | 32201.186±0.010 | 0.36±0.12 | 0.51±0.28 | 0.67±0.09 |
| 21κ, 12-20κ, 11 | 33222.247±0.010 | 0.26±0.07 | 0.58±0.18 | 0.42±0.10 |
| 22ι, 14-21ι, 13 | 33228.623±0.010 | 0.56±0.11 | 0.95±0.21 | 0.56±0.08 |
| 27δ, 24-26δ, 23 | 33268.165±0.010 | 0.55±0.09 | 0.79±0.15 | 0.66±0.09 |
| 28γ, 26-27γ, 25 | 33276.398±0.010 | 0.79±0.09 | 0.93±0.12 | 0.80±0.10 |
Notes. (a)The full contents of this table can be found in electronic form at Zenodo (see Section 5). All uncertainties correspond to 1σ. (b)Each frequency in the second column is assigned to four rotational transitions: two a- and two b-type ones. Labels α, β, γ, δ, ϵ, ζ, η, θ, ι, κ, λ, correspond to Ka = 0,1, Ka = 1,2, Ka = 2,3, Ka = 3,4, Ka = 4,5, Ka = 5,6, Ka = 6,7, Ka = 7,8, Ka = 8,9, Ka = 9,10, and Ka = 10,11, respectively, for each quartet of lines. As an example, the line at 31101.252 MHz is assigned to the quartet of lines 27β, 26-26β, 25, which means to 270, 26-260, 25, 270, 26-261, 25, 271, 26-260, 25 and 271, 26-261, 25 transitions. (c)Measured frequency assuming a vLSR of 5.83 km s−1 for TMC-1 (Cernicharo et al. 2020). (d)Integrated line intensity (in mK km s−1). (e)Linewidth at half intensity derived by fitting a Gaussian function to the observed line profile (in km s−1). (f)Antenna temperature (in milliKelvin).
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.