Table 2.

Relevant SEXTRACTOR setup parameters for both surveys.

LSST-like Euclid-like
DETECT_MINAREA 4 16
DETECT_THRESH 1.5 1.5
FILTER_NAME default.conv default.conv
DEBLEND_NTHRESH 32 32
DEBLEND_MINCONT 0.001 0.001
CLEAN_PARAM 1.0 1.0
BACK_SIZE 64 256
BACK_FILTERSIZE 3 3