Open Access
Table A.1.
Non-closing systematic uncertainties for M87*.
| Test | 2017 Apr 11 | 2018 Apr 21 | 2021 Apr 18 | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| s | s/σth | n | s | s/σth | n | s | s/σth | n | |||
| lo − hi closure trace phases | 2.8° | 0.5 | 220 | 3.4° | 0.6 | 99 | 2.1° | 0.5 | 4321 | ||
| trivial closure trace phases | 0.3° | 0.0 | 63 | 0.0° | 0.0 | 63 | 0.9° | 0.2 | 1844 | ||
| lo − hi log closure trace amplitudes | 5.4% | 0.5 | 220 | 7.9% | 0.7 | 99 | 3.9% | 0.5 | 4321 | ||
| trivial log closure trace amplitudes | 3.2% | 0.3 | 151 | 7.1% | 0.7 | 63 | 3.3% | 0.5 | 1844 | ||
Notes. Non-closing systematic uncertainties, s (and in units of thermal noise, s/σth), are estimated using various statistical tests for each year. For reference, the number of closure quantities used for each test, n, is listed.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.