Open Access

Table E.2.

Parameters of Gaussian components of the KaVA image shown in Figure 1.

ν Comp. ID S [mJy] R [mas] θ [deg] Major [mas] Tb [K]
(1) (2) (3) (4) (5) (6) (7)
First epoch

22 GHz K 288 ± 19 0.0 0.0 0.038 ± 0.002 6.7 × 1011
C8 48 ± 6 0.591 ± 0.007 194.0 ± 0.66 0.166 ± 0.014 5.8 × 109
C7 13 ± 3 1.725 ± 0.006 183.5 ± 0.22 0.09 ± 0.013 5.5 × 109
C6 22 ± 3 2.439 ± 0.002 180.3 ± 0.06 0.058 ± 0.005 2.1 × 1010
C4 7 ± 1 3.8 ± 0.12 182.9 ± 1.81 1.348 ± 0.24 1.3 × 107
C3 2 ± 1 5.497 ± 0.223 179.3 ± 2.32 1.363 ± 0.446 4.2 × 106
C2 1 ± 1 7.653 ± 0.093 182.5 ± 0.7 0.515 ± 0.186 1.5 × 107
C1 17 ± 5 14.78 ± 0.343 166.4 ± 1.33 2.384 ± 0.686 1.0 × 107
43 GHz K 240 ± 9 0.0 0.0 0.064 ± 0.002 5.2 × 1010
C9 40 ± 4 0.371 ± 0.006 195.8 ± 0.9 0.166 ± 0.012 1.3 × 109
C8 11 ± 4 0.823 ± 0.015 191 ± 1.01 0.12 ± 0.029 6.7 × 108
C7 6 ± 1 1.459 ± 0.035 187.9 ± 1.36 0.421 ± 0.069 3.2 × 107
C6 16 ± 3 2.321 ± 0.017 180.7 ± 0.43 0.231 ± 0.035 2.7 × 108

Second epoch

22 GHz K 309 ± 17 0.0 0.0 0.07 ± 0.003 2.1 × 1011
C8 53 ± 8 0.658 ± 0.016 191.5 ± 1.36 0.284 ± 0.031 2.2 × 109
C6 38 ± 7 2.27 ± 0.041 182 ± 1.03 0.565 ± 0.081 3.9 × 108
C5 2 ± 2 3.137 ± 0.049 177.5 ± 0.89 0.243 ± 0.098 1.3 × 108
C4 7 ± 3 5.03 ± 0.16 179.1 ± 1.82 0.851 ± 0.32 3.2 × 107
C2 2 ± 1 8.489 ± 0.064 181.8 ± 0.43 0.305 ± 0.127 7.6 × 107
C1 16 ± 8 15.21 ± 0.716 165 ± 2.7 2.993 ± 1.433 5.8 × 106
43 GHz K 250 ± 17 0.0 0.0 0.091 ± 0.004 2.7 × 1010
C9 44 ± 6 0.458 ± 0.005 192.6 ± 0.59 0.095 ± 0.009 4.3 × 109
C8 11 ± 5 0.869 ± 0.022 193.7 ± 1.44 0.145 ± 0.044 4.8 × 108
C7 7 ± 3 1.579 ± 0.019 190.2 ± 0.7 0.136 ± 0.038 3.2 × 108
C6 24 ± 4 2.344 ± 0.027 181.8 ± 0.67 0.438 ± 0.055 1.1 × 108

Third epoch

22 GHz K 311 ± 16 0.0 0.0 0.05 ± 0.002 4.1 × 1011
C8 33 ± 4 1.099 ± 0.01 187.5 ± 0.5 0.236 ± 0.019 2.0 × 109
C6 27 ± 4 2.476 ± 0.021 180.7 ± 0.48 0.394 ± 0.042 5.8 × 108
C4 4 ± 2 5.507 ± 0.03 178.5 ± 0.31 0.187 ± 0.059 3.5 × 108
C1 14 ± 7 15.19 ± 0.595 166.8 ± 2.24 2.653 ± 1.191 6.5 × 106
43 GHz K 226 ± 17 0.0 0.0 0.061 ± 0.003 5.4 × 1010
C9 34 ± 7 0.554 ± 0.007 190.2 ± 0.68 0.099 ± 0.013 3.1 × 109
C7 7 ± 3 1.477 ± 0.07 193.9 ± 2.72 0.455 ± 0.14 2.9 × 107
C6 22 ± 5 2.303 ± 0.054 182.6 ± 1.34 0.54 ± 0.108 6.7 × 107

Notes. (1) observing frequency; (2) component identification; (3) flux density; (4) separation from the core; (5) PA with respect to the core; (6) FWHM; (7) brightness temperature

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.