Open Access
Table 1
Detector design parameters, as defined in Fig. 2.
| Antenna | h | a | b | w | |
|---|---|---|---|---|---|
| LFA | 240 µm | 12 µm | 12 µm | 25 µm | |
| HFA | 97.7 µm | 6.0 µm | 2 µm | 55.8 µm | |
| Lens | RLens | CLens | DLens | PLens | |
| LFA | 0.9901 mm | 0.3861 mm | 1.90 mm | 2.00 mm | |
| HFA | 0.5517 mm | 0.2152 mm | 0.940 mm | 1.00 mm | |
| KID | Wc | Wg | Wc,NbTiN | Wg,NbTiN | Althickness |
| LFA | 1.6 µm | 2.2 µm | 14 µm | 24 µm | 40 nm |
| HFA | 1.6 µm | 2.2 µm | 6 µm | 10 µm | 65 nm |