Table 1
Summary of the IRAM 30 m and HIFI detections of C2H.
| Instrument | η MB | HPBW | Int. time | Noise | Δν | Δν | CCH | Freq. range |
|
|
| or band | (′′) | (min) | (mK) | (MHz) | (km s-1) | transition | (MHz) | (K MHz) | ||
|
|
||||||||||
| IRAM 30 m | ||||||||||
| A100/B100 | 0.82 | 28.2 | 614 | 2.5 | 1.0 | 3.4 | N = 1−0 | |||
| J = 3/2−1/2 | 87278.2−87339.6 | 15.90 | ||||||||
| J = 1/2−1/2 | 87392.8−87453.6 | 7.58 | ||||||||
| C150/D150 | 0.68 | 14.1 | 215 | 10 | 1.0 | 1.7 | N = 2−1 | |||
| J = 5/2−3/2 | 174621.1−174682.5 | 58.73 | ||||||||
| J = 3/2−1/2 | 174708.2−174744.9 | 38.09 | ||||||||
| J = 3/2−3/2 | 174796.2−174863.7 | 5.90 | ||||||||
| E3 | 0.57 | 9.4 | 161 | 10 | 1.0 | 1.1 | N = 3−2 | |||
| J = 7/2−5/2 | 261974.3−262023.4 | 110.74 | ||||||||
| J = 5/2−3/2 | 262048.8−262084.4 | 60.63 | ||||||||
| J = 5/2−5/2 | 262191.3−262270.0 | 6.33 | ||||||||
| E3 | 0.35 | 7.0 | 79 | 5.3 | 2.0 | 1.7 | N = 4−3 | |||
| J = 9/2−7/2 | 349311.5−349368.3 | 66.98 | ||||||||
| J = 7/2−5/2 | 349368.3−349421.6 | 60.15 | ||||||||
| J = 7/2−7/2 | 349575.1−349671.8 | 2.35 | ||||||||
|
|
||||||||||
| Herschel /HIFI | ||||||||||
| 1a | 0.75 | 40.5 | 28 | 9.9 | 1.5 | 0.86 | N = 6−5 | |||
| J = 13/2−11/2 | 523941.9−524000.4 | 18.60 | ||||||||
| J = 11/2−9/2 | 524000.4−524061.9 | 18.74 | ||||||||
| J = 11/2−11/2 | − | − | ||||||||
| 1b | 0.75 | 34.7 | 13 | 7.4 | 0.50 | 0.25 | N = 7−6 | |||
| J = 15/2−13/2 | 611237.1−611301.6 | 10.09 | ||||||||
| J = 13/2−11/2 | 611301.6−611364.1 | 9.44 | ||||||||
| J = 13/2−13/2 | − | − | ||||||||
| 2a(†) | 0.75 | 30.4 | 12 | 13.7 | 4.5 | 1.8 | N = 8−7 | |||
| J = 17/2−15/2 | 698487.5−698619.0 | 4.21 | ||||||||
| J = 15/2−13/2 | 698619.0−698738.0 | 4.47 | ||||||||
| J = 15/2−15/2 | − | − | ||||||||
| 2b | 0.75 | 27.0 | 15 | 10 | 6.0 | 2.2 | N = 9−8 | |||
| J = 19/2−17/2 | 785750.0−785875.0‡ | 0.20‡ | ||||||||
| J = 17/2−15/2 | 785875.0−785900.0‡ | 0.20‡ | ||||||||
| J = 17/2−17/2 | − | − | ||||||||
Notes. Columns are, respectively, the instrument or band with which we
detected the C2H emission, the main-beam efficiency
ηMB, the half-power beam width HPBW, the integration
time, the noise level in the spectra, the frequency resolution Δν,
the velocity resolution Δν, the detected C2H rotational transitions, the
frequency range in which we observed the lines, and the frequency-integrated intensity
.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.
