Table 5
Main characteristics of LFI full mission maps.
| Frequency band | |||
|
|
|||
| Characteristic | 30 GHz | 44 GHz | 70 GHz |
|
|
|||
| Centre frequency [GHz] ................................................................................................ | 28.4 | 44.1 | 70.4 |
| Effective beam FWHMa [arcmin] ............................................................ | 32.29 | 27.00 | 13.21 |
| Effective beam ellipticitya ......................................................................... | 1.32 | 1.04 | 1.22 |
| Temperature noise (1°)b [μKCMB] ..................................... | 2.5 | 2.7 | 3.5 |
| Polarization noise (Q and U; 1°)b [μKCMB] ............ | 3.5 | 4.0 | 5.0 |
| Overall calibration uncertaintyc [%] ............................................................. | 0.35 | 0.26 | 0.20 |
| Systematic effects uncertainty in Stokes Id [μKCMB] ............ | 0.19 | 0.39 | 0.40 |
| Systematic effects uncertainty in Stokes Qd [μKCMB] .......... | 0.20 | 0.23 | 0.45 |
| Systematic effects uncertainty in Stokes Ud [μKCMB] .......... | 0.40 | 0.45 | 0.44 |
Notes.
Calculated from the main beam solid angle of the effective beam, Ωeff = mean(Ω). These values are used in the source extraction pipeline (Planck Collaboration XXVI 2016).
Sum of the error determined from the absolute and relative calibration, see Planck Collaboration IV (2016).
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.