Pre-CC input parameters for the mock injection systems.

Parameter Value Description
m1,i [M] 15 Companion mass
m2,i [M] 15 BH progenitor mass
Pi [day] 50 Initial period
ei 0.0 or 0.3 Initial eccentricity
Ωi [rad] 3.00 Initial longitude of the
ascending node
ωi [rad] 6.00 Initial argument of
periastron
ii [rad] 1.05 Initial inclination

vα, i [km s−1] 200.13 Initial system velocity
vδ, i [km s−1] 100.94 components in RA, Dec,
vr,i [km s−1] 51.53 and radial directions

Δm2 [M] 5 CC mass loss
vk [km s−1] 50 Natal kick
θ [rad] 2.01 Kick polar angle
ϕ [rad] 0.995 Kick azimuthal angle
νi [rad] 0.436 True anomaly at CC

Notes. All parameters are identical between the two mock systems except for the initial eccentricity. Horizontal lines distinguish initial parameters for the orbit, the pre-collapse velocities, and parameters associated with the CC (including the true anomaly νi at the moment of explosion).