Open Access
Table 5
Simulation parameters used for closed-loop simulation for a single-stage XAO using the iMZ.
| Simulation parameters | |
|---|---|
| Fried’s parameter r0 Coherence time τ0 Outer scale L0 |
10 cm or 15 cm at λ = 500 nm 5.3 ms or 5.8 ms 25 m |
| WFS | iMZ (1.5 λ/D pinhole and 40/60 beam splitter) |
| WFS wavelength | 1.2 µm |
| Image wavelength | 1.2 µm |
| Pixel size | 20 cm (40 × 40 pixels) |
| Corrector | Perfect DM (no fitting error) |
| Controller | Integrator (g = 0.3) |
| Loop frequency | 1 kHz |
| Delay | 1 frame |
| Pre-corrected modes | Piston, tip, and tilt |
| Noise | Photon noise + read-out noise (σron = 0.1 e−) |
Notes. The turbulent phase screen are generated with the multi-layers model of the simulation tool COMPASS (Ferreira et al. 2018) developed for the SAXO+ (Goulas et al. 2024).
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.