Table F.2.
KS and AD test results for EE and non-EE SNe IIb.
| Parameter | KS (Full) | KS (Cleaned) | AD (Full) | AD (Cleaned) |
|---|---|---|---|---|
| Density Threshold: 0 | ||||
| Full sample: 66 SNe (31.82% EE, 68.18% non-EE), Cleaned sample: 59 SNe (30.51% EE, 69.49% non-EE) | ||||
| ΔM15 | 0.42 (8.01×10−3) | 0.45 (7.43×10−3) | 4.81 (4.05×10−3) | 5.16 (3.05×10−3) |
| Mpeak | 0.23 (3.62×10−1) | 0.29 (2.03×10−1) | 0.23 (2.50×10−1) | 0.36 (2.36×10−1) |
| trise | 0.42 (8.01×10−3) | 0.37 (4.78×10−2) | 4.58 (4.94×10−3) | 1.91 (5.32×10−2) |
| Density Threshold: 0.1 | ||||
| Full sample: 65 SNe (32.31% EE, 67.69% non-EE), Cleaned sample: 58 SNe (31.03% EE, 68.97% non-EE) | ||||
| ΔM15 | 0.42 (9.89×10−3) | 0.45 (9.02×10−3) | 4.75 (4.27×10−3) | 5.07 (3.26×10−3) |
| Mpeak | 0.23 (3.84×10−1) | 0.28 (2.29×10−1) | 0.03 (2.50×10−1) | 0.16 (2.50×10−1) |
| trise | 0.42 (9.89×10−3) | 0.36 (6.15×10−2) | 4.28 (6.34×10−3) | 1.67 (6.67×10−2) |
| Density Threshold: 0.2 | ||||
| Full sample: 55 SNe (38.18% EE, 61.82% non-EE), Cleaned sample: 49 SNe (36.73% EE, 63.27% non-EE) | ||||
| ΔM15 | 0.43 (1.07×10−2) | 0.46 (9.46×10−3) | 4.50 (5.28×10−3) | 5.07 (3.26×10−3) |
| Mpeak | 0.21 (5.21×10−1) | 0.27 (3.31×10−1) | 0.21 (2.50×10−1) | 0.38 (2.32×10−1) |
| trise | 0.37 (3.99×10−2) | 0.32 (1.58×10−1) | 2.52 (3.01×10−2) | 5.73 (1.92×10−1) |
| Density Threshold: 0.3 | ||||
| Full sample: 36 SNe (44.44% EE, 55.56% non-EE), Cleaned sample: 33 SNe (42.42% EE, 57.58% non-EE) | ||||
| ΔM15 | 0.41 (7.24×10−2) | 0.51 (1.89×10−2) | 2.23 (3.92×10−2) | 4.09 (7.49×10−3) |
| Mpeak | 0.25 (5.61×10−1) | 0.31 (3.47×10−1) | -0.64 (2.50×10−1) | -0.29 (2.50×10−1) |
| trise | 0.33 (2.53×10−1) | 0.26 (5.45×10−1) | 0.17 (2.50×10−1) | -0.47 (2.50×10−1) |
| Density Threshold: 0.4 | ||||
| Full sample: 19 SNe (47.37% EE, 52.63% non-EE), Cleaned sample: 18 SNe (44.44% EE, 55.56% non-EE) | ||||
| ΔM15 | 0.58 (6.03×10−2) | 0.68 (2.07×10−2) | 0.74 (1.63×10−1) | 1.80 (5.88×10−2) |
| Mpeak | 0.34 (5.39×10−1) | 0.40 (3.92×10−1) | -0.56 (2.50×10−1) | -0.39 (2.50×10−1) |
| trise | 0.47 (2.00×10−1) | 0.43 (2.96×10−1) | 0.30 (2.50×10−1) | -0.29 (2.50×10−1) |
| Explosion Time Error Threshold: 1 | ||||
| Full sample: 18 SNe (55.56% EE, 44.44% non-EE), Cleaned sample: 14 SNe (50.00% EE, 50.00% non-EE) | ||||
| ΔM15 | 0.70 (1.20×10−2) | 0.86 (8.16×10−3) | 3.25 (1.56×10−2) | 6.05 (1.48×10−3) |
| Mpeak | 0.38 (4.85×10−1) | 0.57 (2.12×10−1) | 0.03 (2.50×10−1) | 1.25 (9.95×10−2) |
| trise | 0.58 (7.04×10−2) | 0.43 (5.75×10−1) | 1.01 (1.25×10−1) | -0.59 (2.50×10−1) |
| Explosion Time Error Threshold: 2 | ||||
| Full sample: 34 SNe (38.24% EE, 61.76% non-EE), Cleaned sample: 29 SNe (34.48% EE, 65.52% non-EE) | ||||
| ΔM15 | 0.55 (9.04×10−3) | 0.64 (4.29×10−3) | 2.60 (2.79×10−2) | 3.83 (9.33×10−3) |
| Mpeak | 0.33 (2.78×10−1) | 0.48 (6.66×10−2) | 0.25 (2.50×10−1) | 1.84 (5.65×10−2) |
| trise | 0.44 (6.79×10−2) | 0.33 (3.75×10−1) | 1.60 (7.08×10−2) | -0.32 (2.50×10−1) |
| Explosion Time Error Threshold: 3 | ||||
| Full sample: 46 SNe (39.13% EE, 60.87% non-EE), Cleaned sample: 40 SNe (37.50% EE, 62.50% non-EE) | ||||
| ΔM15 | 0.49 (6.80×10−3) | 0.53 (6.00×10−3) | 3.17 (1.67×10−2) | 3.63 (1.11×10−2) |
| Mpeak | 0.31 (1.93×10−1) | 0.40 (7.74×10−2) | 0.80 (1.54×10−1) | 1.55 (7.45×10−2) |
| trise | 0.51 (3.67×10−3) | 0.44 (3.92×10−2) | 4.91 (3.74×10−3) | 2.01 (4.81×10−2) |
| Explosion Time Error Threshold: 4 | ||||
| Full sample: 56 SNe (37.50% EE, 62.50% non-EE), Cleaned sample: 50 SNe (36.00% EE, 64.00% non-EE) | ||||
| ΔM15 | 0.47 (4.37×10−3) | 0.50 (3.44×10−3) | 4.27 (6.41×10−3) | 4.70 (4.45×10−3) |
| Mpeak | 0.19 (6.67×10−1) | 0.24 (4.23×10−1) | -0.19 (2.50×10−1) | -0.16 (2.50×10−1) |
| trise | 0.49 (2.59×10−3) | 0.43 (2.03×10−2) | 4.89 (3.81×10−3) | 2.33 (3.60×10−2) |
| Explosion Time Error Threshold: 5 | ||||
| Full sample: 61 SNe (34.43% EE, 65.57% non-EE), Cleaned sample: 55 SNe (32.73% EE, 67.27% non-EE) | ||||
| ΔM15 | 0.47 (2.83×10−3) | 0.51 (2.56×10−3) | 4.64 (4.69×10−3) | 5.22 (2.90×10−3) |
| Mpeak | 0.20 (5.41×10−1) | 0.26 (3.32×10−1) | 0.28 (2.50×10−1) | 0.38 (2.33×10−1) |
| trise | 0.43 (7.90×10−3) | 0.37 (4.62×10−2) | 4.31 (6.20×10−3) | 1.79 (5.95×10−2) |
| Explosion Time Error Threshold: 6 | ||||
| Full sample: 66 SNe (31.82% EE, 68.18% non-EE), Cleaned sample: 59 SNe (30.51% EE, 69.49% non-EE) | ||||
| ΔM15 | 0.42 (8.01×10−3) | 0.45 (7.43×10−3) | 4.81 (4.05×10−3) | 5.16 (3.05×10−3) |
| Mpeak | 0.21 (4.84×10−1) | 0.26 (2.89×10−1) | 0.25 (2.50×10−1) | 0.39 (2.30×10−1) |
| trise | 0.42 (8.01×10−3) | 0.37 (4.78×10−2) | 4.58 (4.94×10−3) | 1.91 (5.32×10−2) |
Notes. KS and AD test results comparing EE and non-EE SNe IIb for all density thresholds and explosion time error thresholds. Gray cells highlight statistically significant differences (p-value < 0.05). The number in parentheses indicates the p-value associated with each test statistic.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.