Open Access

Table 3.

Best-fit parameters of the broadband joint spectral analysis for GX 340+0 in the NB obtained by NICER, NuSTAR, and IXPE.

Model Parameter (units) Model A Model B
TBabs NH (1022 cm−2) 9 . 76 0.07 + 0.04 $ 9.76_{-0.07}^{+0.04} $ 9 . 06 0.04 + 0.07 $ 9.06_{-0.04}^{+0.07} $

diskbb kTin (keV) 1 . 303 0.019 + 0.002 $ 1.303_{-0.019}^{+0.002} $ 1.390 ± 0.014
norm ([Rin/D10]2 cos θ) 245 . 8 0.3 + 6.5 $ 245.8_{-0.3}^{+6.5} $ 181 6 + 7 $ 181_{-6}^{+7} $

comptt T0 (keV) 1 . 706 0.032 + 0.004 $ 1.706_{-0.032}^{+0.004} $ 1.72 ± 0.03
kT (keV) 3 . 199 0.042 + 0.004 $ 3.199_{-0.042}^{+0.004} $ 3.18 ± 0.07
τ 3 . 564 0.010 + 0.013 $ 3.564_{-0.010}^{+0.013} $ 3 . 1 0.2 + 0.3 $ 3.1_{-0.2}^{+0.3} $
norm 0 . 3069 0.0144 + 0.0005 $ 0.3069_{-0.0144}^{+0.0005} $ 0 . 267 0.013 + 0.012 $ 0.267_{-0.013}^{+0.012} $

Gaussian E (keV) 6 . 62 0.04 + 0.05 $ 6.62_{-0.04}^{+0.05} $
σ (keV) 1 . 00 0.05 + 0.03 $ 1.00_{-0.05}^{+0.03} $
norm (photon cm−2 s−1) 0.013 ± 0.001
Equivalent width (eV) 11 . 95 0.03 + 0.01 $ 11.95_{-0.03}^{+0.01} $

relxillNS Emissivity 2 . 30 0.13 + 0.20 $ 2.30_{-0.13}^{+0.20} $
Rin (ISCO) 1.2 ± 0.2
Rout (GM/c2) [1000]
Inclination (deg) 33 3 + 2 $ 33_{-3}^{+2} $
log ξ 2 . 77 0.08 + 0.10 $ 2.77_{-0.08}^{+0.10} $
AFe 1 . 5 0.2 + 0.4 $ 1.5_{-0.2}^{+0.4} $
log N [19]
norm (10−3) 1 . 20 0.12 + 0.08 $ 1.20_{-0.12}^{+0.08} $

χ2/d.o.f. 1793/1690 = 1.1 1898/1687 = 1.1

Cross normalisation factors
CNICER [1.0] [1.0]
CNuSTAR − A 1 . 295 0.001 + 0.009 $ 1.295_{-0.001}^{+0.009} $ 1 . 301 0.007 + 0.011 $ 1.301_{-0.007}^{+0.011} $
CNuSTAR − B 1 . 264 0.001 + 0.010 $ 1.264_{-0.001}^{+0.010} $ 1 . 270 0.007 + 0.010 $ 1.270_{-0.007}^{+0.010} $
CIXPE − DU1 0.878 ± 0.006 0.861 ± 0.006
CIXPE − DU2 0.890 ± 0.006 0.870 ± 0.006
CIXPE − DU3 0.878 ± 0.006 0.860 ± 0.006

Photon flux ratios in 2–8 keV
Fdiskbb/Ftot 0.63 0.66
Fcomptt/Ftot 0.35 0.31
Fgauss, relxillNS/Ftot 0.02 0.03

Notes. The estimated unabsorbed flux in 2–8 keV is ∼1.2 × 10−8 erg s−1 cm−2, corresponding to a luminosity of ∼1.7 × 1038 erg s−1 for a distance to the source of 11 kpc (Fender & Hendry 2000). The errors are reported at 90% CL.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.