Table 1
Overview of the irradiation experiments performed on a H2O:CH3OH:N2(5:5:1) ice and resulting SOMA.
| Sample ID | T1 | T2 | I1[μA] | t1[min] | I2[μA] | t2[min] | ||||||||
| Spot | Spot | Spot | Spot | |||||||||||
| 1 | 2 | 3 | 1 | 2 | 3 | 1 | 2 | 3 | 1 | 2 | 3 | |||
| 1 | 10 K | 300 K | 3 | 3 | 3 | 30 | 30 | 30 | – | 3 | 1 | – | 30 | 30 |
| 2 | 30 K | 200 K | 3 | 3 | 3 | 30 | 30 | 30 | – | 1 | 3 | – | 30 | 30 |
| 3 | 10 K | 200 K | 3 | 3 | 3 | 30 | 30 | 30 | – | 3 | 1 | – | 30 | 30 |
| 4 | 10 K | 200 K | 1 | 1 | 1 | 90 | 90 | 90 | – | 1 | – | – | ∼60a | – |
Notes. For each experiment, three spots were irradiated. The corresponding currents and times for the individual spots at irradiation 1 and 2 were collected below Ix/tx. When values are indicated in the I2, T2, and t2 columns, a secondary irradiation at T2 was performed on the same spot as for the first irradiation. aDue to an issue with the electron gun, the irradiation had to be stopped before 90 min.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.