Number of data channels and response elements in the original and final (optimally binned) response matrix for the main instruments involved in our campaign.

Instrument Original channels Final channels Original elements Final elements
Resolve 36 234 5694 1.6 × 108 2.3 × 106
Xtend 4096 241 8.0 × 106 5.9 × 104
FPMA 2005 248 6.3 × 106 7.6 × 104
RGS1 2855 671 8.2 × 106 1.1 × 106
RGS2 2767 671 7.1 × 106 6.7 × 105
MOS1 800 169 1.3 × 106 1.7 × 104
MOS2 800 183 1.3 × 106 5.2 × 104
pn 3329 162 9.3 × 105 4.4 × 104
MEG 5110 1704 1.7 × 106 3.4 × 105
HEG 4837 1451 5.0 × 105 7.3 × 104