Open Access

Table B.1

Overview of the imaging parameters for continuum and CO line observations.

Continuum 12CO 13CO C18O
HD 9985
Beam size (arcsec×arcsec) 0.58×0.45 0.58×0.46 0.61×0.47 0.61×0.47
Beam PA (°) 36.6 38.1 38.1 38.4
rms noise (μJy beam−1/mJy beam−1 ch−1) 15.9 1.6 0.8 0.6
HD 31305
Beam size (arcsec×arcsec) 0.42×0.25 0.42×0.25 0.45×0.27 0.47×0.27
Beam PA (°) -0.5 0.1 5.6 4.9
rms noise (μJy beam−1/mJy beam−1 ch−1) 21.3 2.7 1.4 1.2
HD 112532
Beam size (arcsec×arcsec) 0.57×0.41 0.58×0.42 . . . . . .
Beam PA (°) -66.4 -66.7 . . . . . .
rms noise (μJy beam−1/mJy beam−1 ch−1) 19.0 2.3 . . . . . .
HD 131960
Beam size (arcsec×arcsec) 1.16×1.05 1.25×1.15 . . . . . .
Beam PA (°) 81.8 76.8 . . . . . .
rms noise (μJy beam−1/mJy beam−1 ch−1) 27.3 4.1 . . . . . .
HD 141960
Beam size (arcsec×arcsec) 0.51×0.40 0.53×0.40 . . . . . .
Beam PA (°) -77.6 -76.4 . . . . . .
rms noise (μJy beam−1/mJy beam−1 ch−1) 14.9 1.8 . . . . . .
HD 144277
Beam size (arcsec×arcsec) 0.63×0.54 0.65×0.54 . . . . . .
Beam PA (°) -81.6 -82.4 . . . . . .
rms noise (μJy beam−1/mJy beam−1 ch−1) 18.0 2.2 . . . . . .
HD 145101
Beam size (arcsec×arcsec) 0.51×0.37 0.52×0.37 0.54×0.42 0.54×0.42
Beam PA (°) -74.2 -77.9 -71.2 -71.0
rms noise (μJy beam−1/mJy beam−1 ch−1) 15.1 1.9 1.0 0.8
HD 152989
Beam size (arcsec×arcsec) 0.37×0.28 0.38×0.29 0.39×0.32 0.40×0.32
Beam PA (°) 88.5 84.6 83.0 84.9
rms noise (μJy beam−1/mJy beam−1 ch−1) 16.1 2.1 1.2 0.9
HD 155853
Beam size (arcsec×arcsec) 0.57×0.40 0.51×0.38 0.57×0.41 0.58×0.41
Beam PA (°) -71.7 -72.6 -73.7 -74.5
rms noise (μJy beam−1/mJy beam−1 ch−1) 15.3 2.4 1.0 0.9
HD 159595
Beam size (arcsec×arcsec) 0.45×0.39 0.42×0.37 . . . . . .
Beam PA (°) -69.7 -73.9 . . . . . .
rms noise (μJy beam−1/mJy beam−1 ch−1) 19.5 5.0 . . . . . .
HD 170116
Beam size (arcsec×arcsec) 0.49×0.41 0.50×0.41 0.52×0.42 0.52×0.42
Beam PA (°) -70.3 -74.4 -74.0 -74.2
rms noise (μJy beam−1/mJy beam−1 ch−1) 13.0 1.7 0.9 0.7
HD 176497
Beam size (arcsec×arcsec) 0.51×0.32 0.49×0.31 . . . . . .
Beam PA (°) 81.7 82.5 . . . . . .
rms noise (μJy beam−1/mJy beam−1 ch−1) 13.0 1.7 . . . . . .

Notes. For systems where we detected circumstellar CO gas (even around the companion star, as in the case of HD 31305), the imaging parameters (size and position angle of the synthesised beam, as well as 1 σ rms noise levels) are provided for all three CO isotopologs in addition to the continuum, while for the other objects the parameters are listed only for the continuum and 12CO measurements. The quoted parameters refer to the naturally weighted data sets for HD 144277 and HD 176497, the tapered data for HD 131960 (Gaussian taper with a size of 1″), and Briggs weighted data (robust=0.5) for the rest of the sample. For the 12CO measurements of HD 155853 and HD 159595, we consider the data cubes produced by neglecting the shortest baseline visibilities (see Sect. 5).

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.