Summary of AIPS tables produced by VIPCALs during the different calibration stages.
| Table | Content | Table | Content |
|---|---|---|---|
| CL1 | Initial calibration table | SN1 | Fringe S/N of all sources |
| CL2 | Applies ionospheric corrections | SN2 | Normalized auto-correlations |
| CL3 | Applies EOP corrections | SN3 | Delay corrections of calibrator scan(s) |
| CL4 | Applies parallactic angle corrections | SN4 | Normalized auto-correlations (after bandpass) |
| CL5 | Applies digital sampling corrections | SN5 | Amplitude scaling |
| CL6 | Applies instrumental delay corrections | SN6 | Residual phase, delay, and rate (science target |
| CL7 | Applies normalization of auto-correlations | or phase reference calibrator) | |
| after bandpass | _________________________________ | ||
| CL8 | Applies amplitude calibration | BP1 | Bandpass corrections |
| CL9 | Applies fringe-fitting solutions to science target(s) | _________________________________ | |
| _________________________________ | TY1 | Initial system temperatures | |
| FG1 | Initial flag table | TY2 | Filtered system temperatures |
| FG2 | Flags antennas missing TY/GC | GC1 | Antenna gain curves |
| FG3 | Flags antennas with no fringe detections over the S/N threshold | NX1 | Index table |