Open Access

Table 1.

Best-fit plasma parameters in each EPIC+RGS spectral fit.

Parameter Combined 0655050101 0824570101 0864810101 0883960101
LBOL (1039 erg/s) 1.68 ± 0.03 1.71 ± 0.03 1.26 ± 0.05 1.69 ± 0.05 2.08 ± 0.05
L BOL corr $ L_{\mathrm{BOL}}^{\mathrm{corr}} $ (1039 erg/s) 2.58 2.92 1.70 2.75 2.33
Hardness 0.097 ± 0.002 0.092 ± 0.004 0.102 ± 0.004 0.103 ± 0.004 0.089 ± 0.004
RMS (%) 12.3 ± 0.3 3.73 ± 0.01 15.34 ± 0.04 7.79 ± 0.01

v LOS xabs $ v_{\mathrm{LOS}}^{\mathrm{xabs}} $ (c) −0.156 ± 0.001 −0.176 ± 0.001 −0.141 ± 0.002 −0.107 ± 0.001 −0.046 ± 0.001
v σ xabs $ v_{\sigma}^{\mathrm{xabs}} $ (km/s) 100 ± 30 50 ± 50 250 ± 250 100 ± 50 480 ± 480
log ξxabs (erg/s cm) 4.06 ± 0.09 3.94 ± 0.15 3.81 ± 0.15 3.97 ± 0.17 1.26 ± 0.17
N H xabs $ N_{\mathrm{H}}^{\mathrm{xabs}} $ (1024/cm2) 0.65 ± 0.21 0.62 ± 0.25 0.33 ± 0.12 0.55 ± 0.31 0.06 ± 0.03
ΔC 53 27 26 21 22
CL (σ) > 5 3.6 3.5 2.9 3.0

v LOS pion $ v_{\mathrm{LOS}}^{\mathrm{pion}} $ (c) −0.082 ± 0.001 −0.006 ± 0.001 −0.079 ± 0.001 0.009 ± 0.001 −0.140 ± 0.001
v σ pion $ v_{\sigma}^{\mathrm{pion}} $ (km/s) 400 ± 400 100 ± 100 100 ± 100 700 ± 560 500 ± 500
log ξpion (erg/s cm) 2.5 ± 0.1 0.94 ± 0.1 1.1 ± 0.1 0.25 ± 0.05 0.05 ± 0.05
L X pion $ L_{\mathrm{X}}^{\mathrm{pion}} $ (1038 erg/s) 0.60 ± 0.09 0.83 ± 0.17 0.42 ± 0.12 1.21 ± 0.28 0.81 ± 0.17
ΔC 42 36 17 24 27
CL (σ) > 5 4.8 < 2.5 3.3 3.6

v LOS cie $ v_{\mathrm{LOS}}^{\mathrm{cie}} $ (c) −0.004 ± 0.017 −0.006 ± 0.001 −0.030 ± 0.004 0.028 ± 0.006 −0.136 ± 0.001
v σ cie $ v_{\sigma}^{\mathrm{cie}} $ (km/s) 7000 ± 3000 350 ± 350 1000 ± 1000 4074 ± 2600 342 ± 342
k T e cie $ kT_{\mathrm{e}}^{\mathrm{cie}} $ (keV) 1.4 ± 0.1 0.18 ± 0.02 2.05 ± 0.23 0.11 ± 0.02 0.07 ± 0.01
L X cie $ L_{\mathrm{X}}^{\mathrm{cie}} $ (1038 erg/s) 1.53 ± 0.32 0.90 ± 0.28 0.92 ± 0.20 2.53 ± 1.12 1.86 ± 0.99
ΔC 41 26 22 21 22
CL (σ) > 5 3.5 3.0 2.9 3.0

Notes. Bolometric luminosities are computed within 10−4 − 102 keV. The root mean square (RMS, in %) was computed using the 0.3−10 keV EPIC-pn light curves (time bin size of 1 ks, taken from B22). L BOL corr $ L_{\mathrm{BOL}}^{\mathrm{corr}} $ indicates the luminosity corrected for photoionised xabs absorption. The spectral hardness (estimated from continuum-only fits) yields the ratio of the hard to soft X-ray luminosities (L2 − 10 keV/L0.3 − 2 keV). The X-ray luminosities of the plasma emitting components refer to the 0.3−10 keV band. The value of ΔC shows the fit improvement; the confidence level (CL) expressed in σ units is computed through MC simulations (see Sect. 4.3) and has an uncertainty of about 0.1σ.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.