Open Access

Table 1.

Imaging parameters characterizing the ground truth, CLEAN, multiscale CLEAN, MEM_GE, uv_smooth_VSK, and u-CLEAN reconstructions for the three single-source configurations (see Fig. 2).

Circle Total flux max xmax ymax FWHMx FWHMy
ground truth 10000 9.81 −1 −1 30 30
CLEAN 11268 7.66 −1 −1 33 33
multi-scale CLEAN 10128 9.02 −1 −1 31 31
MEM_GE 10120 8.60 −1 −1 27 27
uv_smooth_VSK 10013 9.90 −1 0 30 30
u-CLEAN 10245 10.21 −1 0 28 28

ellipse

ground truth 10000 11.05 −11 19 20 40
CLEAN 10977 7.46 −10 19 37 27
multi-scale CLEAN 10060 10.03 −10 19 32 25
MEM_GE 10047 9.54 −10 19 28 19
uv_smooth_VSK 10347 11.73 −10 20 32 22
u-CLEAN 10764 11.25 −10 20 33 22

loop

ground truth 10000 6.43 −5 3 50 30
CLEAN 11209 4.36 −5 2 43 49
multi-scale CLEAN 10079 5.65 −4 0 37 39
MEM_GE 10040 5.59 −4 3 29 32
uv_smooth_VSK 10083 6.42 −5 4 34 36
u-CLEAN 10310 7.33 −8 1 28 31

Notes. The total flux is conceived in counts s−1 cm−2 keV−1, max is expressed in counts s−1 cm−2 keV−1 arcsec−2, and xmax, ymax, FWHMx, FWHMy are conceived in arcsec.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.