Open Access

Table B.2.

Measured radio flux densities of the sources in mJy from the original images at their respective resolutions based on 5σ contours, their respective morphology type* and the calculated Kellermann’s parameter Rk.

Object LOFAR 144 MHz VLA L-band 1.5 GHz VLASS S-band 3 GHz VLA C-band 5 GHz VLA X-band 10 GHz Rk
Flux Type Flux Type Flux Type Flux Type Flux Type
J00418+4021 84 ± 8 E 19 ± 1 E 6.1 ± 0.7QL** E 1.66 ± 0.09 E 0.85 ± 0.05 E 1.83
J00457+0410 - - < 0.1 - < 0.7SE - < 0.05 - 0.050 ± 0.008 C ≲-0.50
J00535+1241 - - 5.2 ± 0.3 I 2.7 ± 0.3QL C 1.89 ± 0.10 I 1.05 ± 0.05 C 0.07
J10255+5140 - - 0.64 ± 0.05 I < 0.5QL - 0.12 ± 0.01 I 0.069 ± 0.008 C -0.24
J11292-0424 - - 0.89 ± 0.05 C 0.8 ± 0.2QL C 0.35 ± 0.02 C 0.19 ± 0.01 C -0.11
J11420+6030 2.3 ± 0.2 I 0.91 ± 0.05 C < 0.6QL - 0.28 ± 0.02 C 0.14 ± 0.01 C 1.15
J12075+1506 - - 2.2 ± 0.1 C 1.1 ± 0.2QL C 0.67 ± 0.04 C 0.34 ± 0.02 C 0.81
J12091+5611 8.2 ± 0.8 I 2.1 ± 0.1 C 1.3 ± 0.2SE I 0.77 ± 0.04 C 0.39 ± 0.02 C 1.71
J12366+5630 4.4 ± 0.4 E 0.93 ± 0.05 C < 0.8SE - 0.32 ± 0.02 C 0.20 ± 0.01 C 1.52
J12562+5652 770 ± 80 E 270 ± 10 I 1130 ± 30SE E 660 ± 30 I 670 ± 30 C 1.53
J13012+5902 0.38 ± 0.06 C < 0.1 - < 0.5SE - < 0.05 - < 0.04 - ≲-1.88
J14052+2555 - - 1.02 ± 0.06 C < 0.6QL - 0.46 ± 0.03 I 0.25 ± 0.02 C -1.14
J14063+2223 - - 1.79 ± 0.09 C 1.5 ± 0.2SE I 0.65 ± 0.03 C 0.37 ± 0.02 C -0.34
J14170+4456 4.7 ± 0.5 E 0.79 ± 0.04 C < 0.5QL - 0.21 ± 0.02 I 0.089 ± 0.010 C -0.94
J14258+3946 0.6 ± 0.1 C 15.0 ± 0.8 C 40 ± 4QL I 55 ± 3 C 51 ± 3 C 2.99
J14475+3455 110 ± 10 E 13.4 ± 0.7 C 6.0 ± 0.6QL C 3.3 ± 0.2 C 1.46 ± 0.07 C 1.34
J15455+4846 13 ± 1 E 2.4 ± 0.1 C 1.4 ± 0.2SE I 0.91 ± 0.05 C 0.50 ± 0.03 I 1.08
J17014+5149 - - 23 ± 1 E 12 ± 1QL I 6.0 ± 0.3 E 2.8 ± 0.1 E 1.24

Notes. * C indicates compact, I is intermediate morphology, and E indicates the presence of diffuse emission. ** For VLASS images, QL stands for a Quick Look image data product, while SE stands for a Single Epoch continuum image data product. The parameter RK has been computed as the ratio between the K-corrected flux at 1.4GHz and the optical one at 5100 Å.

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.