Design parameters for the ERIS gvAPP including the inner working angle (IWA) and outer working angle (OWA).

Parameter Value
IWA [λ/D] 2.2
IWA contrast 10−4
OWA [λ/D] 15
OWA contrast 10−5
Encircled energy of airy core 50.9%