Table 4
Overview of derived abundances and uncertainties (σ) organized by atomic number.
| Element | [X/Fe] | [X/H] | σ | Comment | Used lines | Reference |
|---|---|---|---|---|---|---|
| [dex] | [dex] | [dex] | [Å] | |||
| C I | −0.10 | −2.70 | 0.33 | – | 4300 (CH band) | [1] |
| N I | 0.75 | −2.00 | 0.25 | – | 3360 (NH band) | |
| O I | 0.68 | −1.92 | 0.41 | UL | 6300.30 | [2] |
| Na I | −0.34 | −2.94 | 0.25 | – | 8183.26, 8194.82 | |
| Mg I | 0.36 | −2.24 | 0.11 | – | 5528.40, 5711.08 | [3] |
| Al I | −0.85 | −3.45 | 0.44 | LL | 3961.52 | [4] |
| Si I | 0.29 | −2.31 | 0.19 | LL | 3905.52, 7034.90, 7918.38, 7944.00 | [5] |
| K I | 0.58 | −2.02 | 0.20 | – | 7698.98 | |
| Ca I | 0.23 | −2.43 | 0.13 | – | 6102.72, 6162.17, 6169.06, 6169.56 | [6] |
| Sc II | 0.02 | −2.58 | 0.06 | – | 5031.01, 5526.79 | [7] |
| Ti II | 0.33 | −2.27 | 0.07 | – | 4708.67, 5185.91, 5226.55, 5336.79, 5381.02 | [8] |
| V I/II | 0.15 | −2.45 | 0.26 | – | 3951.96, 4002.93, 4005.71, 4379.23 | [9] |
| Cr I | −0.23 | −2.83 | 0.08 | – | 5204.50, 5208.41, 5247.58 | [10] |
| Mn I | −0.50 | −3.10 | 0.20 | LL | 4030.76, 4033.07, 4034.49 | [11] |
| Fe I | 0.00 | −2.60 | 0.19 | – | 3443.87, 3475.45, 3490.57, 3815.84, 3840.43, 3841.04, 3856.37 3872.50, 3949.95, 4134.67, 4210.34, 4271.15, 4271.76, 4299.23 4404.75, 4494.56, 4920.50, 5269.53, 5328.03, 5371.49 | [12] |
| Fe II | 0.00 | −2.60 | 0.19 | – | 4233.17, 4296.57, 4416.83, 4508.28, 4520.22, 4629.33, 4731.45 4923.92 , 5316.61, 5534.84, 6247.55, 6432.68, 6456.38, 6516.08 | [13] |
| Co I | 0.16 | −2.44 | 0.23 | – | 3845.47, 4121.32 | [14] |
| Ni I | 0.06 | −2.54 | 0.23 | – | 7110.90, 7748.88, 7788.93, 7797.58 | |
| Zn I | 0.34 | −2.26 | 0.07 | – | 4810.53 | [15] |
| Sr II | −0.01 | −2.61 | 0.20 | LL | 4077.71, 4215.52 | [16] |
| Y II | −0.18 | −2.78 | 0.11 | – | 3774.33, 5087.43, 5200.42, 5205.73 | [17] |
| Zr II | 0.39 | −2.21 | 0.07 | – | 3499.57, 4050.33, 4208.99 | [18] |
| Ba II | −0.84 | −3.44 | 0.12 | – | 5853.70, 6141.70, 6496.90 | |
| Eu II | −0.02 | −2.62 | 0.16 | UL | 4129.72 | [19] |
Notes. The comment indicates an UL or LL, due to weak lines or saturation. Lines used in this study are listed in column 6. [1] Masseron et al. (2014); [2] Magg et al. (2022); [3] Rhodin et al. (2017); [4] Roederer & Lawler (2021); [5] Den Hartog et al. (2023); Rhodin et al. (2024); [6] Den Hartog et al. (2021); [7] Lawler et al. (2019); [8] Lawler et al. (2013); [9] Wood et al. (2014); Lawler et al. (2014); Holmes et al. (2016); Wood et al. (2018); [10] Sobeck et al. (2007); [11] Den Hartog et al. (2011); [12] Belmonte et al. (2017); Den Hartog et al. (2014); Ruffoni et al. (2014); [13] Den Hartog et al. (2019); [14] Wood et al. (2013); Lawler et al. (2018); [15] Roederer & Lawler (2012); Bergeson & Lawler (1993); [16] https://www.nist.gov/pml/atomic-spectra-database; [17] Hannaford et al. (1982); Biémont et al. (2011); [18] Ljung et al. (2006); Malcheva et al (2006); [19] Lawler et at (2001).
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.